Why timing matters
For that equipment, the documented status clears after the connected device is removed and the bus enters sleep. This scenario alone does not justify replacing the communication module.
HERMES is the communication module used for connected services. In this documented scenario, diagnostic traffic through OBD causes the status; it does not establish a failed module. A third-party adapter may also be fitted behind the socket trim. This connection with the message can be investigated before considering module removal.
Establish whether an OBD adapter remains connected and whether the message returns in ordinary use. The sequence of events can be more informative than a single dashboard photograph.
When investigation continues
A persistent SOS warning or an actually unavailable service needs separate assessment. Review the exact message, module records and service state together.
Keep the wording verbatim. Combining “services limited” and a different SOS warning into “Mercedes me does not work” loses useful diagnostic information.
Sources and technical notes
Historical bulletin LI54.30-P-066410 v3, 21 May 2019, HERMES codes 360/362/364; not a universal cause of SOS or connected-service issues.