B1FC21CStarter battery voltage outside limits
B1FC21C · Starter battery voltage outside limits
Reported voltage is outside the allowed range. Compare it with actual battery condition and history.
197 Black Series, equipment P98, from code 804 only: special 12 V lithium-ion starter battery. This is not a W213 auxiliary-battery reference.
What you may notice
Central locking may fail to unlock and/or the engine may not start.
Possible causes in the documented case
The described cause is a discharged special lithium-ion starter battery. “Internal fault” wording alone is insufficient for a replacement decision.
What needs checking
Check supply, voltage and battery history through the rear SAM in XENTRY, accounting for this special battery type.
How XENTRY diagnostics helps →Technical details and official source
- Model / validity
- SLS 197 Black Series; P98/804
- Engine / recorded variant
- Variant-dependent
- ECU
- N10/2 SAMR_231
- Recorded wording (editorial translation)
- Starter battery malfunction; voltage outside the permitted range.
- Original code / base / suffix
- B1FC21C / B1FC2 / 1C
- Document
- LI54.10-P-057372, version unreadable, 2013-11-20
- Pages — code / context
- 2 / 1–3
- Publisher
- Mercedes-Benz / Daimler; NHTSA
Explanations are editorial summaries of the document, not a live XENTRY readout. Historical diagnostic directions do not prescribe repairs or software changes for your vehicle.