P300494AdBlue quality deviation reported
P300494 · AdBlue quality deviation reported
The system assesses AdBlue quality as insufficient. Fluid and measurement conditions matter when interpreting this result.
Model 907 only. The table places P300494 in MRD1NFZ despite the general SCR heading; match the actual controller.
What you may notice
Check Engine and an AdBlue warning may appear.
Possible causes in the documented case
The bulletin considers software, concentration deviations, frozen or partly thawed fluid and sensor damage. A warning does not automatically mean a failed tank.
What needs checking
Allow for complete thawing and mixing before interpreting concentration. Compare actual level and quality readings and the software context in XENTRY.
How XENTRY diagnostics helps →Technical details and official source
- Model / validity
- Sprinter 907
- Engine / recorded variant
- OM654
- ECU
- N3/40 MRD1NFZ
- Recorded wording (editorial translation)
- Insufficient AdBlue quality reported.
- Original code / base / suffix
- P300494 / P3004 / 94
- Document
- LI49.20-N-078838, v11, 2026-03-23