P047129Invalid exhaust-back-pressure sensor 1 signal
P047129 · Invalid exhaust-back-pressure sensor 1 signal
CDI61 reports an invalid exhaust-back-pressure sensor 1 signal; suffix 29 is part of this exact record.
166/222 OM642.8 with CDI61/CR61 for these two codes only; six-character CR60LS identifiers in the document are not renamed.
What you may notice
Intermittent power loss, sometimes Check Engine and pressure faults; symptoms may disappear after an ignition cycle.
Possible causes in the documented case
Intermittent resistance at crimped harness contacts is documented.
What needs checking
After guided tests, assess ECU/sensor contacts and records without a status filter; do not assume sensor failure.
How XENTRY diagnostics helps →Technical details and official source
- Model / validity
- 166 / 222 with OM642.8
- Engine / recorded variant
- OM642.8
- ECU
- N3/9 CDI61 / CR61
- Recorded wording (editorial translation)
- CDI61 reports an invalid exhaust-back-pressure sensor 1 signal; suffix 29 is part of this exact record.
- Original code / base / suffix
- P047129 / P0471 / 29
- Document
- LI54.18-P-061568 · v1 · 2015-06-09
- Pages — code / context
- 2 / 1–4
- Publisher
- Daimler AG
- Document version
- 1
- Title: LI54.18-P-061568 · v1 · 2015-06-09 · p. 2
- Meaning: LI54.18-P-061568 · v1 · 2015-06-09 · p. 2
- Symptoms: LI54.18-P-061568 · v1 · 2015-06-09 · p. 1
- Possible causes: LI54.18-P-061568 · v1 · 2015-06-09 · p. 1
- Diagnostic direction: LI54.18-P-061568 · v1 · 2015-06-09 · p. 1–2
- Applicability: LI54.18-P-061568 · v1 · 2015-06-09 · p. 1
Explanations are editorial summaries of the document, not a live XENTRY readout. Historical diagnostic directions do not prescribe repairs or software changes for your vehicle.