P203B31AdBlue level signal missing
P203B31 · AdBlue level signal missing
The controller receives no AdBlue level signal. The record alone does not prove an empty tank.
Model 907 only. The table places P300494 in MRD1NFZ despite the general SCR heading; match the actual controller.
What you may notice
Check Engine and an AdBlue warning may appear.
Possible causes in the documented case
The bulletin considers software, concentration deviations, frozen or partly thawed fluid and sensor damage. A warning does not automatically mean a failed tank.
What needs checking
Allow for complete thawing and mixing before interpreting concentration. Compare actual level and quality readings and the software context in XENTRY.
How XENTRY diagnostics helps →Technical details and official source
- Model / validity
- Sprinter 907
- Engine / recorded variant
- Not specified for the SCR control unit
- ECU
- N118/5 or N141; UDCM2
- Recorded wording (editorial translation)
- No signal from the AdBlue level sensor.
- Original code / base / suffix
- P203B31 / P203B / 31
- Document
- LI49.20-N-078838, v11, 2026-03-23
- Pages — code / context
- 4 / 1–4
- Publisher
- Mercedes-Benz / Daimler; NHTSA
Explanations are editorial summaries of the document, not a live XENTRY readout. Historical diagnostic directions do not prescribe repairs or software changes for your vehicle.